CM400-NHS PC Monitoring Module

CM400-NHS PC Monitoring Module

Introduction


CM400- PC Monitoring Module, adopting the design of modularization, can be used with computer to form a integrated patient monitoring system, which can be used as single-parameter or multi-parameter monitor. It features in small size and abundant functions. And it can monitor synchronously such parameters as ECG, BP, TEMP, blood glucose, and SpO2 for adult, pediatric and neonate.

More details

CM400-NHS

Loyalty program No reward points for this product.


3 other products in the same category:

Features


◆Be applicable for adult, pediatric and neonate for all-round monitoring.
◆Real-time display data on PC.
◆Data list and trend graph review.
◆Set interface according to user requirement.
◆Case data and alarm data can be saved in computer hardware.
◆Visual and auditory alarm for parameters and technology. Upper and lower limit of alarm can be adjusted as user's need.
Performance


ECG


◆Waveform: three-lead/full-lead
◆Gain: 2.5mm/mV, 5mm/mV, 10mm/mV, 20mm/mV.
◆HR measuring range: 15bpm~300bpm, error: ±1bpm or ±1%, whichever is greater.
◆Upper and lower limit for ECG alarm range:15bpm~300bpm, resolution: 1bpm.
◆Input circuit current: ≤0.1μA.
◆Enduring polarization voltage: adding ±300mV DC polarization voltage, the variation range of sensitivity is 5%.
◆CMRR: filtering mode(monitor /surgery) ≥ 80dB.
◆Amplitude frequency characteristic: 1~75Hz(-3dB,+0.4dB ).
◆Low frequency characteristic: time constant ≥3.2 s.
◆ECG analysis: heart rate, arrhythmia analysis, ST-segment analysis.
◆ST-segment analysis range: -2.0mV~2.0mV.


BP


◆Measuring method:oscillometry
◆Measuring mode: manual/automatic/continuous.
◆Interval of automatic measurement: adjustable among 1~90 min.
◆Resolution: 1mmHg.
◆Measuring accuracy: maximal average deviation is no more than±5mmHg, and standard deviation is no more than 8mmHg.
◆Self-check function.
◆Overpressure protection: software and hardware double overvoltage protection.
a. Measuring range.


Adult:


Systolic pressure: 40mmHg~270mmHg
Average pressure: 20mmHg~235mmHg
Diastolic pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Average pressure: 20mmHg~165mmHg
Diastolic pressure: 10mmHg~150mmHg
Neonate:
Systolic pressure: 40mmHg~135mmHg
Average pressure: 20mmHg~110mmHg
Diastolic pressure: 10mmHg~100mmHg
b. Upper and lower limit of alarm


Adult:


Systolic pressure: 40mmHg~270mmHg
Average pressure: 20mmHg~235mmHg
Diastolic pressure: 10mmHg~215mmHg
Pediatric:
Systolic pressure: 40mmHg~200mmHg
Average pressure: 20mmHg~165mmHg
Diastolic pressure: 10mmHg~150mmHg


Neonate:


Systolic pressure: 40mmHg~135mmHg
Average pressure: 20mmHg~110mmHg
Diastolic pressure: 10mmHg~100mmHg
c. Interval of automatic measurement:
1/2/3/4/ 5/10/15/30/60/90min, error: <10s.


TEMP


◆Channel         single channel
◆Measuring range              0 ~ 50°C
◆? Resolution        0.1°C
◆Accuracy         0.1°C
Blood glucose
◆Sample         capillary whole blood
◆Sample type for calibration     vein plasma
◆Blood size        about 3ul
◆Test range        2.2mmol/L~27.8mmol/L(40mg/dL~500mg/dL)
◆Test time         25 seconds
◆Calibration curve       automatically select test curve by the correction number
◆Memory         220 results


SpO2


◆Continuous real-time measuring.
◆Adopt digital SpO2 technology, which has strong anti-interference capability.
◆Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph.
◆Trend graph with the function of adaptive scaling
◆Standard adult finger-clip probe, binding probe for neonatal is optional.
a. SpO2 saturation
Measuring range        0 ~ 100 %
Accuracy     
                         70% ~ 100%, ±2%
                         0% ~ 69%, unspecified
b. Pulse Rate
Range: 0bpm~250bpm(Resolution: 1bpm)
Accuracy: ±2bpm or ±2%, whichever is greater.
c. Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%, SpO2 error is ±4%; the Pulse rate error is ±2bpm or ±2%, whichever is greater.
d. Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Standard accessories
◆An user manual
◆A power cord
◆A power adapter
◆A USB cable
◆A SpO2 probe
◆A BP cuff
◆A BP extension cable
◆An ECG cable
◆A temperature probe
◆A communication cable of Blood Glucose Meter
◆A Blood Glucose Meter
◆A software disk.
Physical Characteristic:
Dimension         189(L)×125(W)×41(H) mm
Net Weight         0.5 Kg

 
    
            
     
            
 

    